Thermodynamic water heater and single-flow CMV - T.Flow Hygro+ by ALDES
Recover the calories from the air extracted by room ventilation by heating your domestic hot water with the 2-in-1 T.Flow Hygro+ system from ALDES!
Description of the ALDES T.Flow Hygro+ extract air thermodynamic water heater
- Intelligent ventilation, use of stale air energy for the production of domestic hot water,
- Up to 75% energy saving,
- Humidity-controlled or self-adjusting CMV,
- 200 liter enamelled tank with 55 mm insulation and RAL9006 painted metal jacket,
- Tank protection by titanium anode and starting magnesium anode,
- 1500 W soapstone auxiliary resistance,
- 800 W extract air heat pump with inverter compressor and G4 protection filter,
- Digital display for use and installation adjustment,
- Display of active functions (heat pump, resistance, anti-legionella) and operating information (hot water setpoint temperature, hot water available, filter status),
- 4 operating modes: auto, boost, comfort, vacation,
- For Individual house (B200-FAN T.Flow Hygro+) and collective housing (B200 T.Flow Hygro+),
- New And Renovation,
- Daily need for domestic hot water for 2 to 6 people,
- Works with humidity-controlled and self-adjusting vents,
- Patented system Certified NF Electricté Performance,
- Eligible for the CEE: BAR-TH-148.
Technical characteristics
Tips for installing the T.Flow Hygro+ extract air thermodynamic water heater
The place of installation must meet the following conditions:
• Compliance with NFC15-100 criteria: The water heater must be installed in volume 3 or outside volume,
• Installation in the heated space recommended to guarantee optimum system thermal performance (if this is not possible, the product must be installed in a frost-free room).
• As this water heater operates on extracted air, it must be ducted; consequently there is no restriction on the volume of the installation room
• Stable floor that can support a weight of 350 kg minimum (surface under the water heater).
• Imperative level surface (drainage of condensates).
• Closed room with acoustic partitions and door.
• Avoid installing the product near rooms at night (acoustic comfort). If this is not possible, provide soundproofing of the closet.
• As close as possible to the draw-off points in order to minimize energy losses through the pipes.
• Check easy access to the cover fixing screws (front panel and cover) for any maintenance operations.
• Height under ceiling > 2.3 m necessary for possible dismantling of the upper cover during any repair operations.
• Minimum area required (see diagram opposite): depending on the position and type of water pipe, the available width must be adjusted to ensure that the product remains maneuverable for an after-sales service.