Fixing anchors or roof hooks are used to fix the rail that supports the sensor to the roof.
Dimensions of the slate roof anchor:
For the installation of the fixing anchors, the realization of a trimmer is necessary.
Installation of slate roof anchors
We use at least 4 anchors for 1 sensor, 8 anchors for 2 sensors and 12 anchors for 3 sensors.
The distance between the rails must be 1 m for horizontal mounting and 0.70 m for vertical mounting, to be adjusted according to the pitch of the roof.
The sensors are fixed on the rails thanks to the low and high legs.
Anchors for slate roofing and flat tiles must be fixed in the rafters (possibly crossing the boarding).
The adjoining roofing elements must be cut at the level of the passage of the anchors.
To restore the watertightness of the cover, it is necessary to use 2 lead sheets: before positioning the anchor, place a sheet of lead under the anchor; once the anchor is fixed, place a second sheet of lead covering the anchor.